Discover what you can build in the City of El Segundo. This city guide covers essential Custom Home regulations and zoning laws to help you navigate the process and make informed decisions for your property.
Up to one Custom Home and one JCustom Home can be built on a single-family lot in El Segundo.
Multifamily property owners in El Segundo may convert existing uninhabitable space into at least one Custom Home, and additional Homes not to exceed a maximum number equal to 25% of the existing units. Ergo:
No more than two detached Homes may be constructed on a multifamily lot in El Segundo.
A detatched Custom Home in El Segundo can be up to 1,200 square feet.
An attached Custom Home in El Segundo can be up to 1,200 square feet, or 50% of the size of the primary dwelling unit, whichever is smaller.
A detached Custom Home in El Segundo can be no more than 16 feet hight. An attached Custom Home can be up to the height of the primary dwelling unit, though not to exceed 25 feet.
A two-story Custom Home may be permitted in El Segundo as long as height restrictions are adhered to.
No, Homes cannot be stacked one on top of each other on two stories in El Segundo.
Two Homes are only permitted on multifamily property. El Segundo regulations do not specify the configurations, and two attached Homes may be permitted on a case-by-case basis.
No, a JCustom Home is defined as A Custom Home converted from existing space within the main structure of the primary dwelling unit. As such, it cannot be attached to A Custom Home.
Generally roof decks would be permitted on A Custom Home, but must meet the height restrictions for the zone. Roof decks cannot encroach into the required setbacks. As a rule of thumb, railings and access staircases above 42″ need to be included in height calculations.
In El Segundo the Custom Home must match the architectural design of the proposed or existing structure. This includes using the same exterior material, roof material, color, and architectural details of the main dwelling unit.
Homes behind the primary dwelling unit in El Segundo require a minimum of 4-foot side and rear setbacks.
El Segundo does not specify specific building separation for Homes from the primary dwelling unit or other structures. Enough separation must be maintained to comply with fire codes and reduce the risk of fires spreading from one building to another. Separation requirements will be determined in the planning stage.
Homes are generally not allowed in the front yard in El Segundo.
Not necessarily. Online submission of plans may be available through the online EZ Permit Hub offered by the El Segundo Community Development Department.
El Segundo may require a soils report for Custom Home permitting to make sure the soil can support the new structure, especially if the Custom Home will be located on a hillside, an area with significant grading, or if there are special foundation requirements.
El Segundo specifies no specific requirements for “green” space or permeable surface on your landscaping when constructing A Custom Home. However, green space and permeable surface may become an issue in the approval process if the Custom Home covers a significant portion of the lot.
The plan check requires a review by the Building and Safety Division for zoning, building standards, and safety compliance. The process takes approximately 4-6 weeks.
El Segundo requires one new parking space be added per new Custom Home. However, if the property is within one mile of a public transit stop and/or if the Custom Home or JCustom Home in question is being converted from existing space within the main dwelling unit, the Custom Home is exempt from the requirement of extra parking.
If a parking space must be added, it can be included on the driveway or any setback areas, and it may be configured as tandem parking.
Per Title 24 of the California Energy Code, solar panels of appropriate size and capacity are mandatory on new-construction Homes. Homes built from converted existing structures are exempt, as may be Homes located under significant shading. Smaller Homes may be subject to reduced or modified solar panel requirements.
A Custom Home is not required to have a separate water or electrical meter. You can opt for the Custom Home to share service with the main dwelling unit. However, you can request separate water or electrical meters from the City of El Segundo.
El Segundo does not automatically assign a new Custom Home its own address. However, it may assign the Custom Home a new address if it is intended for rental or independent occupancy. The Custom Home will usually get a “½” designation — for example, A Custom Home located behind 1234 Pine Street would have the address “1234½ Pine Street.”
Low Impact Development (LID) is an approach to land development or redevelopment that seeks to preserve and conserve onsite water quality and natural features, with minimal detrimental effect to local waterways and ecosystems. El Segundo may require LID fees for larger Homes.
A Custom Home may not be used as an Airbnb or short-term rental in El Segundo.
Per the Costa-Hawkins Act of 1995, El Segundo does not impose rent control on dwellings constructed after February 1, 1995. This means most new-build Homes are exempt. However, if the primary dwelling unit is subject to rent control, it might apply to the Custom Home as well.
While encouraging the use of electric appliances for efficiency and sustainability, El Segundo does not prohibit gas appliances in new Homes as long as all relevant installation and safety standards are met.
In El Segundo you are only required to install sprinklers in a new Custom Home if the primary dwelling unit has them as well. You may also be required to install them if the Custom Home is located within a special fire hazard zone.